Jacuzzi ProTech LCD Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Kuchyně Jacuzzi ProTech LCD. Jacuzzi ProTech LCD User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - LCD Series Owner’s Manual

2003+ ProTechTMLCD Series Owner’s Manual

Strany 2 - Attention New Spa Owner!

4.0 Choosing A LocationIMPORTANT: Because of the combined weight of the spa, water andusers, it is extremely important that the base upon which the s

Strany 3 - Table of Contents

US/Canada J-350/J-360/J-370 Models (60Hz)240V/50A* 240V/60A** 240V/30A***Voltage: 240 VAC 240 VAC 240 VACNumber of Wires: 3 3 3Frequency: 60Hz 60Hz 60

Strany 4

Export J-380 Models (50Hz)230V/40A* 230V/35A**Voltage: 230 VAC 230 VACNumber of Wires 3 3Frequency: 50Hz 50HzCurrent Draw: 32A 26ACircuit Breaker: 40A

Strany 5 - 2.0 FCC Notice

Page 96.0 Electrical Wiring InstructionsIMPORTANTNOTICE: The electrical wiring of this spa must meetthe requirements of the National Electrical Code

Strany 6

Page 10BLUEBLUEBROWNBROWN12US/Canada J-350 / J-360 / J-370 / J-380 Models: 240 VAC, 3-Wire Connection (60Hz)Figure-DTB1All Export J-350 / J-360 / J-3

Strany 7

7.0 Start-Up InstructionsCongratulations! You are now all set to get your new spa ready to use. Simplyfollow this step-by-step procedure and, before

Strany 8 - 3.3 CAUTIONS

7.5 Add Start-Up ChemicalsAdd the spa water chemicals as recommended by your Jacuzzi PremiumDealer. Refer to section 13.0 (Page 39) for general guida

Strany 9

8.2 LCD DisplayA. Lock Symbol indicates panel, set temperature, or filter cycle programming is locked.B. Heat Symbol: indicates heater is on (Sec. 9.1

Strany 10 - 4.0 Choosing A Location

189101611112226347171713185661412515Page 141. Control Panel2. Air Controls3. Filter/Skimmer BagCover4. Diverter Valve #25. Maxx PowerPro Jets6. Powe

Strany 11 - 5.0 Power Requirements

Page 158.4 Jet/Air Controls Diagram (J-380 & J-370)Air Control OperationDepress Air Controls A-E to Open orClose Air Inlet to Designated Jet Group

Strany 12 - Export J-380 Models (50Hz)

Attention New Spa Owner!Congratulations on the purchase of your new Jacuzzi Premium spa! Thefollowing is a list of automated functions performed by y

Strany 13

Page 168.5 Jet/Air Controls Diagram (J-360 & J-350)Air Control OperationDepress Air Controls A-D to Open orClose Air Inlet to Designated Jet Group

Strany 14 - Behind Load Box

Page 179.0 Operating InstructionsYour Jacuzzi Premium spa has a touch-sensitive control panel, diverter valves,and air control knobs located on the t

Strany 15 - 7.0 Start-Up Instructions

Page 18then repeatedly press the sensor pad to turn the light off or to select one of6 constant colors illustrated below.You must press the LIGHT sens

Strany 16 - 8.0 Control Functions

Page 19tocustomize the massage and performance by diverting waterbetween various jet systems. Simply turn massage selectorto position A (Combo), B, o

Strany 17 - 8.2 LCD Display

Page 20press it’s release button to unlatch the “pop-up” mechanism. To retracteach speaker before covering spa, gently press downward on each speaker

Strany 18 - 8.3 Spa Features And Controls

D. Adjust TreblePress blue SEL button two times toselect treble mode. Then press blueVOL or VOL button to adjust treblerange from -7 to +7.E.

Strany 19

Page 22H. Bass BoostPress grey LOUD button to increase the bass output. LOUD appears on the display. I. Set ClockPress and hold grey DISP button for

Strany 20

Page 23B. Select a Radio Station1. Slow Scan:Press blue + button or - button for less than one secondto advance radio frequency up or down one step.

Strany 21 - 9.0 Operating Instructions

Page 24D. Recall a Station Preset1. Press grey BAND button to selectdesired radio band, if necessary.2. Press green PRESET button to recall station p

Strany 22 - 9.5 Activate Pump 2/Pump 3

Page 25Optional Stereo Receiver - CD Player OperationA. Insert and Eject CD1. Press orange OPENbutton on front flip-over panel. Gently push a CD int

Strany 23

Table of Contents1.0 Important Spa Owner Information ...12.0 FCC Notice...

Strany 24 - SEL/SEL/

Page 26E. Shuffle Play All TracksPress green SHF button to play all tracks on CD in random order one time. Press again to stop shuffle play.F. Scan (

Strany 25

Page 27Stereo Receiver SpecificationsOptional Stereo Receiver SpecificationsCD PlayerSignal/noise ratio . . . . . . . . . . . . . . . . . . . . . . .

Strany 26

Page 2810.0 Automatic Filtration CyclesYour new spa includes a programmable 24-hour circulation pump whichfilters the water continuously while using l

Strany 27 - 5 SCN 6

Page 29Summer Logic: In warm weather, the water temperature in the hot tub mayexceed the set temperature. This condition may occur due to heat transfe

Strany 28

Page 3011.0 Programming Instructions11 .1 Adjusting Time of DayThe control system remembers the time of day even in the event of a prolonged power ou

Strany 29 - EJECT CD

Page 31With each press, the currently programmed duration will be shown in thelarge four-digit display. Press WARMER ( + ) or COOLER ( - ) to adjustdu

Strany 30

Page 32The factory default start time is 12:00AM (Midnight). The default durationis 24 hours. To make adjustments, press the sensor labeled CYCLE fi

Strany 31

Page 33of day. All automatic spa functions will operate normally.To Unlock The Panel: Press DISPLAY, MODE, and COOLER ( - ), in order,within five se

Strany 32

Page 34To ensure optimum performance, clean and reuse the skimmer bag and bothcartridges once a month, or as needed. ALWAYS TURN POWER TO SPAOFF BEF

Strany 33 - 10.5 Clean-Up Cycle

Page 35*Note: to maximize filter life, switch filter cartridge positions at each cleaning.Periodically, both filter cartridges will need a more thorou

Strany 34 - 11.0 Programming Instructions

9.10 Air Controls...199.11 Optional Jacuzzi Premium

Strany 35

Page 36CAUTION: There are certain precautions to keep in mind whendraining your spa. If it is extremely cold, and the spa is outdoors,freezing could o

Strany 36 - 11 .6 Panel Lock

Page 37To remove pillows:1. Grasp center pillow insert (A) with finger tips and gently pry outward from pillow base (C).2. Use a standard screwdrive

Strany 37 - 12.0 Spa Maintenance

Page 3812.8 WinterizingYour Jacuzzi Premium spa is designed to automatically protect itself againstfreezing when operating properly. During periods o

Strany 38 - Cartridge 2

Page 39spa from operating properly and possibly damaging the equipment. We rec-ommend you consult your dealer for guidance before attempting to re-sta

Strany 39 - 12.2 Draining and Refilling

cosmetic water treatment and others simply alter the feel or smell of thewater. Your Authorized Jacuzzi Premium dealer can advise you on the useof the

Strany 40 - 12.4 Pillow Care

Page 4114.0 Troubleshooting - Display MessagesThere are a number of unique functions designed into your Jacuzzi Premiumspa to protect it from damage

Strany 41 - 12.5 Maintaining the Cover

Page 42automatically re-activate if no sensor is pressed for 30seconds. Circuit board temperature has exceeded acceptablelimit. This message will dis

Strany 42 - 12.8 Winterizing

Page 4315.0 Troubleshooting - ProceduresIn the unlikely event your spa is not working the way you believe it should,please first review all installat

Strany 43 - 0 Water Quality Maintenance

Page 44Note: This method must be used for the single speed pump(s) in all spasbecause pump #2 (and J-380 pump #3) are not connected to the filter. CAU

Strany 44

Page 4516.0 Wiring DiagramJ-350/J-360/J-370 Models (USA/Canada 60Hz)Power Input: 240 VAC, 60A / 50A / 30A 1 PHASE, 60Hz; USE MIN. 6 AWG COPPER CONDUC

Strany 45

1.0 Important Spa Owner InformationYour Jacuzzi® Premium spa is constructed to the highest standards and iscapable of providing many years of trouble

Strany 46

Page 4617.0 Wiring Diagram J-380 Models (USA/Canada 60Hz)SENSORSPower Input: 240 VAC, 60A / 50A / 40A1 PHASE, 60Hz; USE MIN. 6 AWG (10 mm2)COPPER CON

Strany 47

Page 47Power Input: 230-240 VAC, 40A / 30A / 20A 1-Phase, 50Hz; USE MIN. 6 AWG (10 mm2)COPPER CONDUCTORS ONLYJ8J3TB7TB1TB1TB6TB5TR4TR2J6 J7OPTIONS SEN

Strany 48

Page 4819.0 Wiring Diagram J-380 Models (Export 50Hz)Power Input: 230-240 VAC, 40A / 35A 1-Phase, 50Hz; USE MIN. 6 AWG (10 mm2) COPPER CONDUCTORS ONL

Strany 49 - Transformer T1

Page 49TB1TB1Red (L2)PigtailNeutral BusGroundBlack (L1)GreenMainServicePanelwithGFCI2-Pole GFCIBreakerGround LugBonding LugBonding Lug2-Pole Circuit B

Strany 52 - 19.0 Wiring Diagram

Jacuzzi® Premium14525 Monte Vista Ave. • Chino, CA 91710Website: http://www.jacuzzipremium.com6530-224, Rev. D © 2002 Jacuzzi Premium Printed in U.S.A

Strany 53 - US/Canada 60Hz Models Only

3.0 IMPORTANT SAFETY INSTRUCTIONSWhen installing and using this electrical equipment, basic safety pre-cautions should always be followed, including:

Strany 54

B. Since excessive water temperatures have a high potential for causing fetaldamage during the early months of pregnancy, pregnant or possibly preg-na

Strany 55

C. WARNING: People with infectious diseases should not use a spa.D. WARNING: To avoid injury, exercise care when entering or exiting the spa.E. WARNIN

Strany 56 - Jacuzzi® Premium

2. The Consumer Products Safety Commission has stated that the water temperature in a spa should not exceed 104 °F (40 °C). Immersion inwater in exces

Komentáře k této Příručce

Žádné komentáře